Principle of online X-ray thickness measurement
Background:
Modern production technology requires faster and more accurate quality control technology to ensure the overall quality of products. Our company has introduced relevant equipment and technology from Europe and cooperated with domestic top scientific research institutes to develop and produce PSD-500 thickness (weight) online detection system. This system is a detection device that can detect and feedback the thickness or weight of various films, fabrics and non-woven fabrics, coated fabrics, composite materials and other products in real time. Especially in BOPP and BOPET
Working Principle:
For X-ray, after it penetrates the tested material, the attenuation rule of ray intensity I is I=Ioe - μd; Io is the initial ray intensity, I is the ray intensity after passing through the object, μ Is the absorption coefficient, d is the thickness through which the ray passes (gram weight);
When μ and Io are fixed, I is only a function of the measured material d, so the thickness (gram weight) d can be known by measuring I. The principle of the X-ray thickness (gram weight) detector is to convert the thickness or gram weight according to the intensity attenuation when the X-ray penetrates the measured object, that is, measure the X-ray energy absorbed by the measured object, and determine the thickness (gram weight) of the measured product according to the energy value of the X-ray. The received signal is converted into electrical signal by the X-ray receiver, amplified by the preamplifier, and then converted into the actual thickness value or figure for people to watch by the processing system.
Main Functions:
1. Fixed point measurement: the position of fixed point measurement can be set arbitrarily within the scanning range
2. Automatic completion of timing calibration or manual calibration, and the time interval of timing calibration can be set
3. Position compensation calibration
4. Automatic detection, display and processing of system faults
5. Screen display:
*Display the transverse distribution of the measured material thickness according to the working mode of the system scanning measurement or fixed-point measurement
Current value, maximum value, minimum value, average value, mean square deviation and deviation value of curve or longitudinal distribution curve
*The parameter modification screen displays the configuration parameters and can modify the parameters
*Display system working status and fault type
6. Response time of the system: ≤ 0.5 seconds
Product Advantages:
X-rays originally belong to low energy output, and will not produce any radiation when the power is turned off
The equipment has been exempted by the environmental protection department, and users do not need to go through the application and filing procedures, which is convenient to use
Be able to flexibly adapt to the use environment with many varieties, complex processes and strict quality requirements in various industries
With position compensation function
Clean design will not cause any pollution to the tested product
Application Field:
Film
Sheet
Artificial leather
Metal rolling: aluminum foil, copper foil and steel strip
Composite material: coating impregnated products
Fabrics and non-woven fabrics
Rubber plate
Technical Parameters:
Measuring range: 10~6000 μ m
Measurement accuracy: ± 0.5% or ± 1 μ M (whichever is higher)
Scanning speed: 1.0~6m/min
Power supply voltage: AC220 500W
Working temperature: 0-50 ℃